Product Description
SKX****0SUP description The waveform type description ( using the
PM***0 monitor detection ) 1, waveform code 1: normal ECG waveform
The data rate of *0 BPM for *0: code The frequency range of *****0
BPM wave amplitude is fixed, is not affected by the amplitude
effect 2, 2: a triangular waveform waveform code Data code for the
*5 *5bpm Frequency range: *****0bpm Range 0.**4mV, the amplitude
adjustment adjustment. 3, waveform code 3: Fang Bo Data code for
the *0 1Hz 0.***0Hz Range 0.**4mV, the amplitude adjustment
adjustment. 4, 4: sinusoidal waveform code Data code for the *0
*0Hz ****0Hz Range 0.**4mV, the amplitude adjustment adjustment. 5,
the code for the 5:QRS wave waveform You can change the amplitude
of T wave, QRS wave amplitude, width of QRS wave, QRS wave
frequency To change the parameters through the combination of keys
6, 6: respiratory waveform waveform code Data code for *0bpm
Respiratory waveform frequency adjustment range *****0 7, waveform
code 7: pacing pulse signal pacing signal of positive and negative
direction Data code for *0mS ( 2mS ) The frequency of *0bpm Range
is *1.*4mV, the amplitude adjustment adjustment. Through the
combination of positive and negative direction switch You can
change the pulse width, the range of 0.**2mS 8, waveform code 8:
QRS wave front pacing signals Lead pacing signal for positive and
negative pulse waveform, through a combination of key switch Lead
pacing signal pulse width can be adjusted, the range of 0.**2mS
Range is *1.*4mV, the amplitude adjustment adjustment. 9, waveform
code 9: adjust the waveform amplitude Data code for the **0 1Mv **0
4Mv *0, waveform code for A: Data code for the 1 *5bpm normal Data
code for the 2 **0bpm heartbeat tachycardia Data code for the **5
BPM heartbeat bradycardia Data code for the ***0 BPM T
supraventricular heartbeat tachycardia Data code **0 ( *3 ) BPM
drain Bo Data code for the **4 BPM agonal rhythm Data code for the
*0 BPM arrest *1, the code for the B: Data code for the 1 *5bpm
normal Data code for the 2 *2bpm NSR with PAC Data code for the 3
*2bpm rough type of atrial fibrillation, irregular heartbeat 4
*0bpm room early data code 5 *0bpm 2 consecutive ventricular
premature data code ( 2 ventricular extrasystole) 6 *0bpm 3
consecutive ventricular premature data code ( multiple ventricular
premature ) 7 *0bpm 4 consecutive ventricular premature data code (
multiple ventricular premature ) Data code for the 8 *0bpm
premature beats Data code for the 9 *0bpm 2 consecutive beats Data
code for the *0 *0bpm 4 consecutive beats s Data code for the *1
*0bpm 1 beats, a normal waveform Data code for the *2 *0bpm all
PVCs ( VF / VT ) *2, waveform code for C: Data code for the 1 *0bpm
degree block Data code for the 2 *5bpm degree block *5 BPM Data
code for the 3 *1bpm degree block *1 BPM Data code for the 4 *0bpm
L bnd1 branch block Data code for the 5 *0bpm R bnd1 branch block
*3, waveform code for D: Data code 1 ( ****3 ) BPM ATRIAL PAC Data
code for the 2 *0bpm pvc1 early Lv focus Data code for the 3 *0bpm
pvc1 early Rv focus Data code for the 4 *0bpm nodal PNC Data code
for the 5 *0bpm two premature ventricular bigeminy Data code for
the 6 *0bpm premature ventricular trigeminy Data code for the 7
*0bpm R ON T
Country: |
China |
Model No: |
skx-2000sup
|
FOB Price: |
483 / Unit (Negotiable)
Get Latest Price
|
Place of Origin: |
Xuzhou, Jiangsu, China |
Price for Minimum Order: |
483 per Unit |
Minimum Order Quantity: |
1 Unit |
Packaging Detail: |
Packing delicate drop resistance |
Delivery Time: |
1-2 days can be shipped |
Supplying Ability: |
100 Unit per Week |
Payment Type: |
Western Union |
Product Group : |
ECG monitoring equipment category
|